Non-contact fluid conductivity sensor

The sensor allows non-contact measurement of the electrical conductivity of liquids.

To determine the conductivity of a liquid, a unique technology of non-contact conductivity measurement is used, which excludes contact of the measuring electrodes with the liquid.
The flow of electrolytic processes on the surface of the measuring electrodes, which are always accompanied by the release of electrolysis products and contamination of the liquid, is excluded.


Contacts are located in the same plane.
Measures the temperature of a liquid.


The sensor is available in flat and cylindrical versions as shown in the pictures below.

Areas of use

  • Separation of products at medium electrical conductivity (milk/water)
  • Separation of products at high electrical conductivity (alkaline solution/water)
  • Measurement of the electrical conductivity of aggressive liquids
  • Drinking water preparation/treatment
  • Cleaning of drains

Advantages

  • Various designs available for optimal adaptation to specific process conditions and installation methods
  • Low supply voltage, suitable for mobile applications
  • Compact design
  • Supplied with connector or fixed cable

Main Technical Characteristics

Conductivity ranges: from 0,1 µS/cm to 10 µS/cm; from 1 µS/cm to 100 µS/cm; from 100 µS/cm to 10 mS/cm

Accuracy: ± 1%

Operating principle: impedance

Supply voltage: 2,8-5,5 V

Temperature sensor: thermistor

Electrical connection: cable (built-in 0.5m 4-core shielded wire)

Working temperature: from -25 to 70 ºC

Housing material: Plastic, ABS 

Dimensions: flat 40х20х8 mm, cylindrical diameter 12 mm length 50 mm
Weight: 30 g

 

Digital sensor interface provides connection to digital controllers